Conway Piling were contracted in, to provide precast piling works for a Housing Development in Allenwood.

The job consisted of 96No fully reinforced precast concrete piles. Conway Piling supplied and installed 96No 250mm sq. x 250mm sq. precast piles.

We had an Independent Pile testing company in for Dynamics and CAPWAP analysis. 

Pile design was also done by our Independent Pile design company. 

Conway Piling were contracted by Campion Construction Ltd, to provide precast piling works for New Housing Development, Shannon Street, Mountrath.

This job consisted of 163No precast piles. Conway Piling supplied and installed the 163No 200mm sq. x 200mm sq. fully reinforced concrete piles.

We had an Independent Pile testing company in for Dynamics and CAPWAP analysis. 

Pile design was also done by our Independent Pile design company. 

Vibration Monitoring was in place for the duration of the works.

Conway Piling were contracted in by Owen Dervin & Sons to supply and install 11No 150mm dia and 11No 220mm dia bottom driven steel tube mini piles to max depths achieved on site.

Pile design was done by own independent pile design company. 

We piled for the substation and for the footpath at the New Primary Care Centre. 

Dynamics and CAPWAY testing were done by our independent pile testing company.

Athlone Boat Club was founded in 1835, flood after flood, June 2020 was time to build a New Club House. 

Conway Piling were contracted in for the piling works for Athlone Boat Club.

We were to supply and install 34No 275mm sq. x 275mm sq. precast concrete piles to max depths achieved on site.

With works progressing extremely well, Athlone Boat Club hope to be settled into their new home mid-2021.

Our final project of 2020, we carried out installation of Vinyl Sheet Piles to protect a property which was in danger of eroding away.

Block boundary wall was taken away and replaced with Vinyl Sheet Piles installed to 3500mm below ground and finishing at a height of 1500mm above ground and "capped" to replace boundary wall.

There was both mini piling and precast piling on site. Conway Piling supplied and installed 27No 320mm sq. x 320mm sq. precast concrete piles to max depths achieved on site. Along with 26No 220mm dia bottom driven minimum vibration steel tube mini piles to max depths achieved on site. Our PM20 Junttan rig was on site for the precast piling, along with out Hanex for the mini piling works.

© 2022 Conway Piling Limited • Registered with the CRO as Company No. 270776